Interphase-tech RAS Communications Controller 5536 Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Interphase-tech RAS Communications Controller 5536. Interphase Tech RAS Communications Controller 5536 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Users Guide

ENTIA™ 5536 DM PRIRAS Communications ControllerUsers GuideDocument No. UG05536-000-D3Release Date: July 2002

Strona 2

any provision of this Agreement is held invalid, illegal, or unenforceable, the remaining provisions shall in no way be affected or impaired thereby.

Strona 3 - Trademark Acknowledgments

Hardware Management80 Interphase CorporationSetting Up ISDN Port PropertiesIf the 553x ISDN RAS Support driver is installed on the machine, you can us

Strona 4 - World Wide Web

Chapter 5: Setting Up WAN Firmware and Hardware5536 PRI RAS Communications Controller Users Guide 81Use the ISDN PRI Port Properties dialog box to vie

Strona 5 - Safety Precautions

Hardware Management82 Interphase CorporationIf you change to a switch type that uses fewer ISDN B channels, you must remove unused ISDN and digital mo

Strona 6

Chapter 5: Setting Up WAN Firmware and Hardware5536 PRI RAS Communications Controller Users Guide 83Figure 5-4. DS1 PropertiesClock Settings, Line Fr

Strona 7

Hardware Management84 Interphase CorporationConfiguring the CSUIf you have selected an American switch type, you can edit CSU properties for the board

Strona 8 - END-USER LICENSE AGREEMENT

Chapter 5: Setting Up WAN Firmware and Hardware5536 PRI RAS Communications Controller Users Guide 85Setting Up Digital Modem Port PropertiesIf the 553

Strona 9

Hardware Management86 Interphase CorporationCards section of the WAN Adapters setup dialog box, as shown in the following illustration:Figure 5-5. Di

Strona 10

Chapter 5: Setting Up WAN Firmware and Hardware5536 PRI RAS Communications Controller Users Guide 873. To set the speech coding law, select A Law for

Strona 11 - 1Contents

Saving WAN Setup Properties88 Interphase Corporationd. When a message informs you that RAS is being stopped, select Remote Access Server and click Sta

Strona 12 - Contents

65536 PRI RAS Communications Controller Users Guide 896Setting Up CallsOverviewThis chapter provides detailed information about setting up outgoing an

Strona 13

5536 PRI RAS Communications Controller Users Guide i1ContentsUsing This Guide...

Strona 14

Setting Up or Removing Channels as RAS Ports90 Interphase CorporationSetting Up or Removing Channels as RAS PortsIf you need to add ISDN or digital mo

Strona 15

Chapter 6: Setting Up Calls5536 PRI RAS Communications Controller Users Guide 913. Select Remote Access Service from the list of services, and click t

Strona 16

Setting Up or Removing Channels as RAS Ports92 Interphase CorporationThe Remote Access Setup dialog box appears, with the selected channel listed as a

Strona 17 - 1Using This Guide

Chapter 6: Setting Up Calls5536 PRI RAS Communications Controller Users Guide 93The Remote Access Setup dialog box reappears. 8. To quickly add and co

Strona 18 - Text Conventions

Setting Up or Removing Channels as RAS Ports94 Interphase CorporationRemoving RAS Port DesignationsIf you need to remove a channel from the RAS device

Strona 19 - Documentation Updates

Chapter 6: Setting Up Calls5536 PRI RAS Communications Controller Users Guide 95Setting Up RAS Support PropertiesUsing the Interphase RAS support dial

Strona 20 - Driver Updates

Setting Up RAS Support Properties96 Interphase CorporationFollowing is an illustration of the two versions of the General dialog box:Figure 6-4. RAS

Strona 21 - 1Introduction

Chapter 6: Setting Up Calls5536 PRI RAS Communications Controller Users Guide 974. View or configure general ISDN or Digital Modem RAS support paramet

Strona 22

Setting Up RAS Support Properties98 Interphase CorporationYou are prompted to restart the computer.6. Continue as follows:– If the system is a basic W

Strona 23 - Hardware Overview

Chapter 6: Setting Up Calls5536 PRI RAS Communications Controller Users Guide 991. From the Start menu, select Settings, and then Control Panel. Then

Strona 24 - 4 Interphase Corporation

Contentsii Interphase CorporationCompleting the MVIP Bus Connection...25CHAPTER 3 Connecting to the LineOverview...

Strona 25 - Software Overview

Setting Up RAS Support Properties100 Interphase CorporationIn the Incoming Filter dialog box, call numbers to be accepted by the ISDN RAS driver appea

Strona 26 - Utilities

Chapter 6: Setting Up Calls5536 PRI RAS Communications Controller Users Guide 101Moving an Incoming Call Number Up or DownTo rearrange incoming call n

Strona 27 - RAS Management Tool

Setting Up Call Properties102 Interphase Corporation• From the Card Properties dialog box, click the Call Setup button.Following is the Call Setup di

Strona 28 - RAS Support Overview

Chapter 6: Setting Up Calls5536 PRI RAS Communications Controller Users Guide 103Call Setup Display ColumnsOn the left side of the Call Setup dialog b

Strona 29 - SecurID Support Overview

Setting Up Call Properties104 Interphase CorporationChannel Type Identifies the types of call the card accepts on a Port or a Service: • Data 64K or

Strona 30 - 10 Interphase Corporation

Chapter 6: Setting Up Calls5536 PRI RAS Communications Controller Users Guide 105Call Setup FieldsThe fields available on the right side of the Call S

Strona 31 - SDpasscode). The

Setting Up Call Properties106 Interphase CorporationYou can select multiple ports of the same type in the tree view (that is, multiple ISDN or COM por

Strona 32 - Minimum System Requirements

Chapter 6: Setting Up Calls5536 PRI RAS Communications Controller Users Guide 107NOTEMake sure that each channel type selected for each digital modem

Strona 33 - Chapter 1: Introduction

Setting Up Outgoing Call Properties108 Interphase CorporationSetting Up Outgoing Call PropertiesOutgoing calls handled by the communications controlle

Strona 34 - 14 Interphase Corporation

75536 PRI RAS Communications Controller Users Guide 1097Managing SerialDriver COM PortsOverviewThe Serial driver for the communications controller is

Strona 35 - Hardware

Contents5536 PRI RAS Communications Controller Users Guide iiiCHAPTER 5 Setting Up WAN Firmware and HardwareOverview...

Strona 36 - Inspecting the Board

Setting Up Serial Driver COM Ports110 Interphase CorporationSetting Up Serial Driver COM PortsDuring software installation, eight Serial COM driver po

Strona 37 - Installing the Board

Chapter 7: Managing Serial Driver COM Ports5536 PRI RAS Communications Controller Users Guide 1114. When you are prompted to choose a port on which to

Strona 38 - 18 Interphase Corporation

Declaring Serial Driver Modems in Windows NT112 Interphase Corporation9. When a message informs you that the modem has been set up successfully, click

Strona 39

Chapter 7: Managing Serial Driver COM Ports5536 PRI RAS Communications Controller Users Guide 113up networking needs to be configured because the list

Strona 40 - 20 Interphase Corporation

Verifying COM Ports114 Interphase CorporationNOTEHyperTerminal is a standard feature of Windows NT. If it is not present in the Accessories menu, it c

Strona 41

Chapter 7: Managing Serial Driver COM Ports5536 PRI RAS Communications Controller Users Guide 1154. Click OK to confirm the parameters. (The parameter

Strona 42 - Connecting to an MVIP Bus

Verifying COM Ports116 Interphase Corporation

Strona 43

85536 PRI RAS Communications Controller Users Guide 1178TroubleshootingOverviewThis chapter provides possible solutions for common problems you might

Strona 44 - 24 Interphase Corporation

Interpreting LEDs118 Interphase CorporationInterpreting LEDsThe 5536-DM RAS board provides four LEDs above each PRI port:Figure 8-1. LED ArrangementL

Strona 45 - Modem Connection LEDs

Chapter 8: Troubleshooting5536 PRI RAS Communications Controller Users Guide 119In their operational state, the LEDs are as follows:The following tabl

Strona 46 - 26 Interphase Corporation

Contentsiv Interphase CorporationSaving Call Setup Properties ...107Setting Up Outgoing Call Proper

Strona 47 - 3Connecting to the

Interpreting LEDs120 Interphase CorporationE1/PRI Interface With CRC4On cards with an E1/PRI interface and CRC4 (most European countries other than Fr

Strona 48 - T1/PRI Line

Chapter 8: Troubleshooting5536 PRI RAS Communications Controller Users Guide 121E1/PRI Interface Without CRC4On cards with an E1/PRI interface and no

Strona 49 - Up to 6200 feet (1.8 km)

Interpreting LEDs122 Interphase CorporationThe following table describes the board status when the sequence of LEDs appears as follows:4 Red OffLED1 L

Strona 50 - WAN Adapter Telco

Chapter 8: Troubleshooting5536 PRI RAS Communications Controller Users Guide 123Problems and Possible SolutionsProblem Possible Solution(s)The card is

Strona 51 - T1 Link Requirements

Problems and Possible Solutions124 Interphase CorporationLoopTest failed 1. Check the cable connection between the board and the ISDN network.2. Make

Strona 52 - E1/PRI Line

Chapter 8: Troubleshooting5536 PRI RAS Communications Controller Users Guide 125Digital Modem RAS Dial-out failedThe following possible solutions assu

Strona 53 - E1 Link Requirements

Problems and Possible Solutions126 Interphase CorporationISDN remote station failed to connect to the RAS ServerIf you do not know how to access the R

Strona 54 - Connector Pinouts

Chapter 8: Troubleshooting5536 PRI RAS Communications Controller Users Guide 127PSTN remote station failed to connect to the RAS ServerIf you do not k

Strona 55 - Connecting to the Network

Problems and Possible Solutions128 Interphase CorporationMultilink is not enabled in the RAS phonebook entry propertiesSelect the Enable Multilink opt

Strona 56 - 36 Interphase Corporation

Chapter 8: Troubleshooting5536 PRI RAS Communications Controller Users Guide 129Remote station failed to connect to the RAS Server when SecurID suppor

Strona 57 - Software

Contents5536 PRI RAS Communications Controller Users Guide vWatching ISDN Ports and Channels ...142Watchin

Strona 58 - 38 Interphase Corporation

Problems and Possible Solutions130 Interphase CorporationRemote station failed to connect to the RAS Server when SecurID support is active(continued)O

Strona 59 - Installing the Drivers

A5536 PRI RAS Communications Controller Users Guide 131ADigital ModemMonitor UtilityOverviewThe Digital Modem Monitor Utility, or DM Monitor utility,

Strona 60 - 40 Interphase Corporation

Viewing Digital Modem Monitor Information132 Interphase CorporationNOTEThe 5536-DM RAS is listed as the 5536-1P-PRI or the 5536-2P-PRI in the Digital

Strona 61

Appendix A: Digital Modem Monitor Utility5536 PRI RAS Communications Controller Users Guide 133The status bar at the bottom of the dialog box displays

Strona 62 - 42 Interphase Corporation

Selecting Digital Modem Monitor Options134 Interphase CorporationDisplay OptionsUse the Display dialog box to select columns to be displayed on the Di

Strona 63

Appendix A: Digital Modem Monitor Utility5536 PRI RAS Communications Controller Users Guide 135• Local number • Remote number of the connection• IS

Strona 64 - 44 Interphase Corporation

Selecting Digital Modem Monitor Options136 Interphase CorporationTimer OptionsUse the Timer dialog box to change the polling period, which is expresse

Strona 65

Appendix A: Digital Modem Monitor Utility5536 PRI RAS Communications Controller Users Guide 137The polling period you select is taken into account as

Strona 66 - 46 Interphase Corporation

Displaying Connection Properties138 Interphase CorporationThe properties of the selected connection appear in a message box. In the following example,

Strona 67

B5536 PRI RAS Communications Controller Users Guide 139BUsing the SynWatchUtilityOverviewThe SynWatch utility is a protocol analyzer that enables you

Strona 68 - 48 Interphase Corporation

Contentsvi Interphase CorporationAlarm LEDs ...173Error LEDs ...

Strona 69 - Completing the WAN Setup

Accessing Online Help140 Interphase CorporationAccessing Online HelpFor detailed information about the functions described in this appendix, see the S

Strona 70 - 50 Interphase Corporation

Appendix B: Using the SynWatch Utility5536 PRI RAS Communications Controller Users Guide 141Figure B-1. Main SynWatch Dialog BoxThe main SynWatch dia

Strona 71

Watching ISDN Ports and Channels142 Interphase Corporation• Fourth level: Channels available on a portEach PRI port has one ISDN D channel. Each PRI p

Strona 72 - 52 Interphase Corporation

Appendix B: Using the SynWatch Utility5536 PRI RAS Communications Controller Users Guide 143• To start watch activity on an unwatched port or channel

Strona 73

Watching ISDN PRI Layer 1 Alarms144 Interphase CorporationThe following illustration shows the menu of watch modes for a B channel or a port:Figure B-

Strona 74 - 54 Interphase Corporation

Appendix B: Using the SynWatch Utility5536 PRI RAS Communications Controller Users Guide 145Stopping and Freezing the DisplayTo stop frame watching an

Strona 75

Changing Display Settings146 Interphase CorporationThe Watch dialog box appears.Figure B-4. Channel Watch Settings2. In the Size of a watched frame f

Strona 76 - 56 Interphase Corporation

Appendix B: Using the SynWatch Utility5536 PRI RAS Communications Controller Users Guide 147Changing Fonts Used for Display TextTo change the font col

Strona 77

Changing Display Settings148 Interphase Corporation4. To change the font for all display text, click the Font button. On the Font dialog box, select t

Strona 78 - 58 Interphase Corporation

Appendix B: Using the SynWatch Utility5536 PRI RAS Communications Controller Users Guide 1492. Select the PRI alarms Color tab to display the PRI alar

Strona 79

5536 PRI RAS Communications Controller Users Guide vii1Using This GuidePurposeThis Users Guide provides information about the Interphase ENTIA™ DM RAS

Strona 80 - 60 Interphase Corporation

Modifying Event Buffer Parameters150 Interphase CorporationModifying Event Buffer ParametersYou can modify the number of low-level events you want Syn

Strona 81

Appendix B: Using the SynWatch Utility5536 PRI RAS Communications Controller Users Guide 1512. In the Buffer Type section, select one of the following

Strona 82 - 62 Interphase Corporation

Saving and Editing Frames152 Interphase Corporation

Strona 83

C5536 PRI RAS Communications Controller Users Guide 153C LoopTest UtilityOverviewThe LoopTest utility enables you to check your ISDN line quickly and

Strona 84 - 64 Interphase Corporation

Testing the ISDN Line154 Interphase CorporationTesting the ISDN LineLoopTest tests the board’s ISDN line by establishing two ISDN B channels in a loop

Strona 85 - Removing the Drivers

Appendix C: LoopTest Utility5536 PRI RAS Communications Controller Users Guide 155The LoopTest main dialog box appears:Figure C-1. LoopTest Main Dial

Strona 86 - 66 Interphase Corporation

Displaying and Saving Events156 Interphase CorporationNOTEIf you want to test more than two B channels or more than one port simultaneously, launch se

Strona 87

Appendix C: LoopTest Utility5536 PRI RAS Communications Controller Users Guide 157To show or hide the LoopTest event list, on the LoopTest main dialog

Strona 88 - 68 Interphase Corporation

Understanding LoopTest Messages158 Interphase CorporationUnderstanding LoopTest MessagesThe Diagnostic field in the main LoopTest dialog displays Loop

Strona 89

Appendix C: LoopTest Utility5536 PRI RAS Communications Controller Users Guide 159Driver Not LoadedThe driver was not in a working state when LoopTest

Strona 90 - 70 Interphase Corporation

Text Conventionsviii Interphase CorporationCAUTIONThe Caution admonition brings to your attention those items or steps that, if not properly followed,

Strona 91 - Firmware and Hardware

Understanding LoopTest Messages160 Interphase CorporationTest failed The connection between the two ISDN B channels could not be established before ti

Strona 92 - 72 Interphase Corporation

Appendix C: LoopTest Utility5536 PRI RAS Communications Controller Users Guide 161Standard ISDN messagesDepending on the cause of an error, LoopTest m

Strona 93

Understanding LoopTest Messages162 Interphase Corporation

Strona 94 - Firmware Management

D5536 PRI RAS Communications Controller Users Guide 163DLine Test UtilityOverviewCAUTIONThe Line Test utility should be used only in cases of trouble

Strona 95

Determining the Current Port Mode164 Interphase CorporationDetermining the Current Port ModeNOTEThe 5536-DM RAS is listed as the 5536-1P-PRI or 5536-2

Strona 96

Appendix D: Line Test Utility5536 PRI RAS Communications Controller Users Guide 1652. Click Select mode to display the Port Test Configuration dialog

Strona 97 - Setting Up Card Properties

Setting Port and Clock Modes166 Interphase CorporationLoopback ModeLoopback mode is a transmission state in which the signal received by the port is r

Strona 98 - 78 Interphase Corporation

Appendix D: Line Test Utility5536 PRI RAS Communications Controller Users Guide 167Figure D-3. Port Options Dialog Box3. Select the LoopTest setting

Strona 99

Setting Port and Clock Modes168 Interphase CorporationWhen this mode is selected, the text message portion of the Line Test main dialog box displays t

Strona 100 - 80 Interphase Corporation

Appendix D: Line Test Utility5536 PRI RAS Communications Controller Users Guide 169In such configurations, the clock of the local port must be in slav

Strona 101 - Configuring the Switch Type

Using This Guide5536 PRI RAS Communications Controller Users Guide ixPressing the return key (↵ Return) at the end of the command line entry is assum

Strona 102 - Editing DS1 Properties

Setting Port and Clock Modes170 Interphase Corporation

Strona 103

E5536 PRI RAS Communications Controller Users Guide 171ELine Status UtilityOverviewThe Line Status utility enables you to see what's wrong when a

Strona 104 - Interphase Corporation

Interpreting Line Status Indicators172 Interphase CorporationNOTEThe 5536-DM RAS is listed as the 5536-1P-PRI or 5536-2P-PRI in the Line Status dialog

Strona 105

Appendix E: Line Status Utility5536 PRI RAS Communications Controller Users Guide 173Alarm LEDsThe following alarm LEDs indicate connection problems t

Strona 106 - 86 Interphase Corporation

Interpreting Line Status Indicators174 Interphase CorporationError LEDsThe following error LEDs indicate port error events that generate communication

Strona 107 - Saving WAN Setup Properties

Appendix E: Line Status Utility5536 PRI RAS Communications Controller Users Guide 175Statistics ParametersThe following statistics fields display perf

Strona 108 - 88 Interphase Corporation

Interpreting Line Status Indicators176 Interphase Corporation

Strona 109 - 6Setting Up Calls

F5536 PRI RAS Communications Controller Users Guide 177FQuick Reference ofCommon TasksOverviewThis section explains how to complete common tasks assoc

Strona 110 - 90 Interphase Corporation

Procedures178 Interphase CorporationProceduresNOTEThe 5536-DM RAS is listed as the 5536 in software dialog boxes. Configure a multilink connection 183

Strona 111 - Chapter 6: Setting Up Calls

Appendix F: Quick Reference of Common Tasks5536 PRI RAS Communications Controller Users Guide 179Determine the server name needed to start the RAS Ser

Strona 112 - 92 Interphase Corporation

NOTESee Appendix I for Regulatory Statements/Conditions that affect the operation of this product.The CE Declaration of Conformity can be found at www

Strona 113

Driver Updatesx Interphase Corporation5. A new web page appears with a list of the latest released user guides available for the product. Click on the

Strona 114 - 94 Interphase Corporation

Procedures180 Interphase CorporationSee if the drivers are running1. From the Start menu, select Programs, then Administrative Tools (Common), and the

Strona 115

Appendix F: Quick Reference of Common Tasks5536 PRI RAS Communications Controller Users Guide 181Open the Remote Access Setup dialog box1. From the St

Strona 116 - General dialog box:

Procedures182 Interphase CorporationConfigure a RAS port to dial out1. Open the Remote Access Setup dialog box. (See Open the Remote Access Setup dial

Strona 117

Appendix F: Quick Reference of Common Tasks5536 PRI RAS Communications Controller Users Guide 183Configure a multilink connectionThe Multilink PPP pro

Strona 118

Procedures184 Interphase CorporationEnable IPX routing The RIP for NWLink IPX Service must be installed in the Windows NT Network Services list.1. Fro

Strona 119

Appendix F: Quick Reference of Common Tasks5536 PRI RAS Communications Controller Users Guide 185Allow a remote user to set a specific IP address1. Fr

Strona 120 - 100 Interphase Corporation

Procedures186 Interphase CorporationSupply an IP address from a static address pool to a remote user1. From the Start menu, select Settings, and then

Strona 121 - Setting Up Call Properties

Appendix F: Quick Reference of Common Tasks5536 PRI RAS Communications Controller Users Guide 187Disconnect an ISDN port automatically when no data tr

Strona 122 - 102 Interphase Corporation

Procedures188 Interphase Corporation

Strona 123 - Call Setup Display Columns

G5536 PRI RAS Communications Controller Users Guide 189GISDN TechnologyOverviewOverviewIntegrated Services Digital Network (ISDN) is an internationall

Strona 124

15536 PRI RAS Communications Controller Users Guide 11IntroductionOverviewThe Interphase 5536 DM RAS communications controller is a single-slot Periph

Strona 125 - Call Setup Fields

Basic Rate Interface190 Interphase CorporationBasic Rate InterfaceThe ISDN Basic Rate Interface consists of three digital channels: one D channel and

Strona 126

H5536 PRI RAS Communications Controller Users Guide 191HSpecificationsBoard SpecificationsOperating EnvironmentItem SpecificationHost Bus Interface PC

Strona 127 - Saving Call Setup Properties

Storage Environment192 Interphase CorporationStorage EnvironmentTemperature -4–185° F / -20–85° C Relative humidity LAN and storage cards: 10–95% no

Strona 128 - RAS Management

I5536 PRI RAS Communications Controller Users Guide 193IRegulatoryStatementsFCC5536-001, 5536-004, 5536-005 DM 2P PRI Communications ControllerFCC Par

Strona 129 - Driver COM Ports

FCC194 Interphase Corporation5536-000, 5536-002, 5536-003 DM 1P PRI Communications ControllerFCC Part 15 Regulatory ComplianceThis equipment has been

Strona 130 - Windows NT

Appendix I: Regulatory Statements5536 PRI RAS Communications Controller Users Guide 1955536-001, 5536-002, 5536-003, 5536-004, 5536-005 DM 1P PRI, 2P

Strona 131

FCC196 Interphase CorporationIf you experience trouble with this equipment, please contact Interphase Corporation at 214-654-5000 for warranty informa

Strona 132 - 112 Interphase Corporation

Appendix I: Regulatory Statements5536 PRI RAS Communications Controller Users Guide 197Canada5536-001, 5536-002, 5536-003, 5536-004, 5536-005 DM 1P PR

Strona 133 - Verifying COM Ports

Canada198 Interphase CorporationUsers should ensure for their own protection that the electrical ground connections of the power utility, telephone li

Strona 134

Appendix I: Regulatory Statements5536 PRI RAS Communications Controller Users Guide 199Europe5536-001, 5536-002, 5536-003, 5536-004, 5536-005 DM 1P PR

Strona 135

Overview2 Interphase CorporationThe 5536-DM RAS software can provide secure connections by interfacing with a Security Dynamics® ACE/Agent® installed

Strona 136 - 116 Interphase Corporation

Europe200 Interphase Corporation

Strona 137 - 8Troubleshooting

5536 PRI RAS Communications Controller Users Guide 201Glossary2B+D  See BRI (Basic Rate Interface).23B+D  See PRI (Primary Rate Interface).30B+D  S

Strona 138 - Interpreting LEDs

Glossary202 Interphase CorporationAsynchronous transmission  Method of sending data in which the interval between characters may be of unequal length

Strona 139 - Chapter 8: Troubleshooting

Glossary5536 PRI RAS Communications Controller Users Guide 203BRI (Basic Rate Interface)  A defined ISDN interface that includes two B channels and o

Strona 140 - E1/PRI Interface With CRC4

Glossary204 Interphase CorporationConfiguration cycle  A type of I/O cycle provided on the PCI bus to facilitate system configuration.CPE (Customer-P

Strona 141 - E1/PRI Interface Without CRC4

Glossary5536 PRI RAS Communications Controller Users Guide 205(ANSI) Standard T1.618 and the International Telegraph and Tele-phone Consultative Commi

Strona 142

Glossary206 Interphase CorporationDistributed Function Terminal (DFT)  1) A protocol used for com-munication between a terminal and an IBM 3270 or IB

Strona 143

Glossary5536 PRI RAS Communications Controller Users Guide 207Excess burst size  (Be) The maximum amount of uncommitted data (in bits) in excess of

Strona 144

Glossary208 Interphase CorporationIEEE (Institute of Electrical and Electronic Engineers)  An infor-mation exchange organization. Among other functio

Strona 145

Glossary5536 PRI RAS Communications Controller Users Guide 209LAP-D (Link Access Procedure-D)  For ISDN, Data Link layer pro-cedure using D channel c

Strona 146

Chapter 1: Introduction5536 PRI RAS Communications Controller Users Guide 3Figure 1-1. 5536-DM RAS Communications ControllerHardware OverviewFollowin

Strona 147

Glossary210 Interphase CorporationMbps (Megabits per second)  Transmission speed or rate of one million bits per second.MBps (Megabytes per second) 

Strona 148

Glossary5536 PRI RAS Communications Controller Users Guide 211NI-1 (National ISDN1)  A specification for a standard ISDN phone line. National ISDN 1

Strona 149

Glossary212 Interphase CorporationPMC (PCI Mezzanine Card)  A daughtercard form factor implemen-tation of the PCI bus specification.POTS (Plain Old T

Strona 150 - REQUIRED)

Glossary5536 PRI RAS Communications Controller Users Guide 213RBOC (Regional Bell Operating Company)  There are seven regional telephone companies cr

Strona 151 - Monitor Utility

Glossary214 Interphase CorporationRS-232  Universally accepted Electronics Industries Association standard that defines the signals between data term

Strona 152 - Information

Glossary5536 PRI RAS Communications Controller Users Guide 215SPID (Service Profile IDentifier)  An alphanumeric string that uniquely identifies the

Strona 153

Glossary216 Interphase CorporationTEI (Terminal Endpoint Identifier)  The Terminal Endpoint Identi-fier is used to identify a specific piece of equip

Strona 154 - Display Options

Glossary5536 PRI RAS Communications Controller Users Guide 217X.21 bis  (Packet data networking) International recommendation that defines the most p

Strona 155

Glossary218 Interphase Corporation

Strona 156 - Timer Options

When using this index, keep in mind that a page number indicates onlywhere referenced material begins. It may extend to the page or pagesfollowing the

Strona 157

Hardware Overview4 Interphase Corporation• CPU mother board:– RISC processor 32-bit PowerPC 403 GCX at 66 MHz– 32-bit local bus at 33 MHz– 8-Mbyte DR

Strona 158 - 138 Interphase Corporation

Index220 Interphase Corporationverifying... 113common tasks, quick reference ... 177communication events, LoopTe

Strona 159 - BUsing the SynWatch

Index5536 PRI RAS Communications Controller Users Guide 221Hhardwareadapter installation... 15electrical warning ...

Strona 160 - Starting SynWatch

Index222 Interphase CorporationLoopTest utility... 6, 153accessing online help ... 153displaying and saving eve

Strona 161

Index5536 PRI RAS Communications Controller Users Guide 223RRAI LED ... 173RAS device, adding... 5

Strona 162 - 142 Interphase Corporation

Index224 Interphase Corporationediting display fonts ... 147editing PRI alarm fonts ... 148editing watch settings ...

Strona 163

Chapter 1: Introduction5536 PRI RAS Communications Controller Users Guide 5Software OverviewThe software package supports up to four 5536-DM boards in

Strona 164 - 144 Interphase Corporation

Software Overview6 Interphase Corporation– RAS support driver for digital modem communications• The SecurID support driver submits, in coordination w

Strona 165 - Changing Display Settings

Chapter 1: Introduction5536 PRI RAS Communications Controller Users Guide 7RAS Management ToolThe Virtual Motion Remote Access Manager Suite, by Aco

Strona 166 - 146 Interphase Corporation

RAS Support Overview8 Interphase CorporationThe Remote Access Manager Suite requires Windows NT 4.0 and the Windows NT Service Pack 3 or higher. For d

Strona 167

Chapter 1: Introduction5536 PRI RAS Communications Controller Users Guide 9Figure 1-2. RAS FeaturesSecurID Support OverviewSecurity for connections t

Strona 168 - 148 Interphase Corporation

Copyright Notice© 2000, 2001, 2002 by Interphase Corporation. All rights reserved.Printed in the United States of America, 2002.This manual is license

Strona 169

SecurID Support Overview10 Interphase CorporationThe present documentation does not describe how to install and setup your ACE/Server and/or ACE/Agent

Strona 170 - 150 Interphase Corporation

Chapter 1: Introduction5536 PRI RAS Communications Controller Users Guide 11Figure 1-4. DialUp Dialog Box for SecurID ConnectionThe User name field c

Strona 171 - Saving and Editing Frames

Minimum System Requirements12 Interphase Corporation• If the ACE/Server grants the access, the communication can continue with the Windows NT authent

Strona 172 - 152 Interphase Corporation

Chapter 1: Introduction5536 PRI RAS Communications Controller Users Guide 13• Microsoft Windows NT Service Pack 3 or higher required for Acotec Remot

Strona 173 - C LoopTest Utility

Minimum System Requirements14 Interphase Corporation

Strona 174 - Testing the ISDN Line

25536 PRI RAS Communications Controller Users Guide 152Installing theHardwareOverviewYou can install the communications controller board in any suitab

Strona 175 - Appendix C: LoopTest Utility

Inspecting the Board16 Interphase CorporationInspecting the BoardBefore installing the communications controller board in your computer, visually insp

Strona 176 - Displaying and Saving Events

Chapter 2: Installing the Hardware5536 PRI RAS Communications Controller Users Guide 17Installing the BoardWARNINGYour computer operates at voltages t

Strona 177

Installing the Board18 Interphase Corporation1. Turn off the computer’s power switch, and unplug the unit from its power source.Figure 2-1. Unpluggin

Strona 178 - LoopTest test results:

Chapter 2: Installing the Hardware5536 PRI RAS Communications Controller Users Guide 19Figure 2-2. Removing the Computer Cover3. Locate a suitable PC

Strona 179

AssistanceProduct Purchased from ResellerContact the reseller or distributor if• You need ordering, service or any technical assistance.• You receiv

Strona 180

Installing the Board20 Interphase Corporation4. Remove the expansion plate.Figure 2-3. Removing the Expansion Plate434343

Strona 181

Chapter 2: Installing the Hardware5536 PRI RAS Communications Controller Users Guide 215. Carefully remove the board from its antistatic bag, and posi

Strona 182 - 162 Interphase Corporation

Connecting to an MVIP Bus22 Interphase Corporation7. Continue as follows:– If you want to connect the board to other 5536 WAN boards in the computer,

Strona 183 - DLine Test Utility

Chapter 2: Installing the Hardware5536 PRI RAS Communications Controller Users Guide 23For optimal electrical signal quality on the MVIP ribbon cable,

Strona 184 - Setting Port and Clock Modes

Connecting to an MVIP Bus24 Interphase CorporationConfiguring MVIP Electrical TerminationIf this is the last board in a multiple MVIP Bus configuratio

Strona 185 - Appendix D: Line Test Utility

Chapter 2: Installing the Hardware5536 PRI RAS Communications Controller Users Guide 25Modem Connection LEDsThe 5536-DM RAS provides an LED for each m

Strona 186 - Loopback Mode

Connecting to an MVIP Bus26 Interphase Corporation

Strona 187 - Loopback mode

35536 PRI RAS Communications Controller Users Guide 273Connecting to theLineOverviewThe methods for connecting your 5536 board to the line depend on w

Strona 188 - Clock Modes

T1/PRI Line28 Interphase CorporationIf the distance is more than 655 feet or 200 meters (up to 6200 feet or 1.8 kilometers), you must connect the boar

Strona 189

Chapter 3: Connecting to the Line5536 PRI RAS Communications Controller Users Guide 29Connecting Directly in a DSX1 ConfigurationYou can connect the b

Strona 190 - 170 Interphase Corporation

Safety PrecautionsThe following general safety precautions must be observed during all phases of operation of this equipment. Failure to comply with t

Strona 191 - ELine Status Utility

T1/PRI Line30 Interphase Corporationyour carrier exceeds 6200 feet or 1.8 kilometers but is less than 6855 feet or 2.0 kilometers.) The following illu

Strona 192 - 172 Interphase Corporation

Chapter 3: Connecting to the Line5536 PRI RAS Communications Controller Users Guide 31T1/PRI Cabling RequirementsThe cable between the board and the c

Strona 193 - Alarm LEDs

E1/PRI Line32 Interphase CorporationE1/PRI LineWhen you connect the board to an E1/PRI line, first determine the appropriate connection method, cablin

Strona 194 - Loopback LEDs

Chapter 3: Connecting to the Line5536 PRI RAS Communications Controller Users Guide 33E1 Link RequirementsIf the board connects to the E1 line, the bo

Strona 195 - Statistics Parameters

Connector Pinouts34 Interphase CorporationConnector PinoutsThe following illustration of the board’s faceplate shows the board’s connectors and connec

Strona 196 - 176 Interphase Corporation

Chapter 3: Connecting to the Line5536 PRI RAS Communications Controller Users Guide 35Connecting to the NetworkWARNINGBefore connecting the cable, rea

Strona 197 - Common Tasks

Connecting to the Network36 Interphase Corporation

Strona 198 - Procedures

45536 PRI RAS Communications Controller Users Guide 374Installing theSoftwareOverviewThis chapter describes the procedures for installing and setting

Strona 199

Verifying Minimum Requirements38 Interphase CorporationReview the Read Me text file on the 5536-DM RAS installation CD before installing the software.

Strona 200 - Figure F-1. Devices List

Chapter 4: Installing the Software5536 PRI RAS Communications Controller Users Guide 39Installing the DriversNOTEBefore you start, make sure the commu

Strona 201

WARNING The ISDN cable(s) must remain disconnected from the telecommunications system until the card has been installed in the system. The install

Strona 202

Installing the Drivers40 Interphase Corporationthe Adapters tab to display the Network Adapters dialog box:Figure 4-1. Network Adapters Dialog Box2.

Strona 203

Chapter 4: Installing the Software5536 PRI RAS Communications Controller Users Guide 41The system creates a driver list in the Select Network Adapter

Strona 204

Installing the Drivers42 Interphase CorporationFigure 4-3. Insert Disk Dialog Box 4. Insert the installation CD-ROM, and change the installation path

Strona 205

Chapter 4: Installing the Software5536 PRI RAS Communications Controller Users Guide 43You can install the 5536 Digital Modem RAS Support driver, the

Strona 206 - Figure F-3. IP Addressing

Setting Up Card and Port Properties44 Interphase CorporationThe installation program copies product files to installation directory, and creates a pro

Strona 207

Chapter 4: Installing the Software5536 PRI RAS Communications Controller Users Guide 45This dialog box enables you to set up 5536 firmware and hardwar

Strona 208 - 188 Interphase Corporation

Setting Up Card and Port Properties46 Interphase CorporationThe Card Properties dialog box appears:Figure 4-7. Card Properties Dialog Box2. Select th

Strona 209 - Overview

Chapter 4: Installing the Software5536 PRI RAS Communications Controller Users Guide 47Figure 4-8. ISDN PRI Port Properties2. Depending on your geogr

Strona 210 - Primary Rate Interface

Setting Up Card and Port Properties48 Interphase Corporation4. If the board has dual ISDN ports, repeat Steps 1 through 3 to configure the remaining I

Strona 211 - HSpecifications

Chapter 4: Installing the Software5536 PRI RAS Communications Controller Users Guide 49– For North America and Japan, select µ Law (Mu Law). 3. Click

Strona 212 - Storage Environment

WARNINGThis equipment generates, uses, and can radiate electromagnetic energy. It may cause or be susceptible to electromagnetic interference (EMI) if

Strona 213 - Statements

Setting Up RAS Support Properties50 Interphase CorporationSetting Up RAS Support PropertiesAfter you finish configuring port properties for RAS suppor

Strona 214 - 194 Interphase Corporation

Chapter 4: Installing the Software5536 PRI RAS Communications Controller Users Guide 51For the Digital Modem RAS Support driver, the driver name in th

Strona 215

Setting Up RAS Support Properties52 Interphase Corporation– If RAS is not installed, a message informs you that RAS support setup is complete, and sta

Strona 216 - 196 Interphase Corporation

Chapter 4: Installing the Software5536 PRI RAS Communications Controller Users Guide 53Setting Up Channels as RAS PortsAfter you respond OK to the mes

Strona 217

Setting Up Channels as RAS Ports54 Interphase CorporationFigure 4-13. Add RAS Device Dialog BoxIn the RAS Capable Devices field, the device name indi

Strona 218 - 198 Interphase Corporation

Chapter 4: Installing the Software5536 PRI RAS Communications Controller Users Guide 55The Remote Access Setup dialog box appears, with the selected c

Strona 219

Setting Up Channels as RAS Ports56 Interphase Corporation4. Select a port usage option, and click OK.The Remote Access Setup dialog box reappears. 5.

Strona 220 - 200 Interphase Corporation

Chapter 4: Installing the Software5536 PRI RAS Communications Controller Users Guide 57Figure 4-16. Network Configuration Dialog Box For NT Servers,

Strona 221 - Glossary

Setting Up Channels as RAS Ports58 Interphase Corporationc. Click OK to save the network configuration.d. Depending on the network settings you config

Strona 222

Chapter 4: Installing the Software5536 PRI RAS Communications Controller Users Guide 59– If you do not need to install another RAS support driver, ski

Strona 223

END-USER LICENSE AGREEMENTFOR INTERPHASE CORPORATION SOFTWAREIMPORTANT NOTICE TO USER–READ CAREFULLYTHIS END-USER LICENSE AGREEMENT FOR INTERPHASE COR

Strona 224

Installing the Remote Access Manager Suite60 Interphase CorporationTo install the Remote Access Manager Suite, do the following:1. When the Virtual Mo

Strona 225

Chapter 4: Installing the Software5536 PRI RAS Communications Controller Users Guide 61CAUTIONYou must finish installing the driver(s) before restarti

Strona 226

Completing the Software Installation62 Interphase CorporationCompleting the Software InstallationAfter you have configured all of the software you hav

Strona 227

Chapter 4: Installing the Software5536 PRI RAS Communications Controller Users Guide 63Do the following to make the installation settings take effect:

Strona 228

Completing the Software Installation64 Interphase CorporationIn addition, you may need to do one or all of the following, depending on your board and

Strona 229

Chapter 4: Installing the Software5536 PRI RAS Communications Controller Users Guide 65Removing the DriversIf you no longer use the communications con

Strona 230

Removing the Drivers66 Interphase CorporationFigure 4-18. Removing a RAS Support Driver3. Select the RAS Support driver to remove, and click Remove.

Strona 231

Chapter 4: Installing the Software5536 PRI RAS Communications Controller Users Guide 67NOTEIf the driver software is only partially installed, the dri

Strona 232

Removing the Drivers68 Interphase Corporationa. Click Continue.The following pop-up prompts you to confirm the card(s) removal and driver deletion: Fi

Strona 233

Chapter 4: Installing the Software5536 PRI RAS Communications Controller Users Guide 69a. Click OK to continue. b. When prompted to restart the comput

Strona 234

responsible for any transportation costs, unless expressly authorized in writing by Seller. This warranty does not cover damage to the Product resulti

Strona 235

Removing the Drivers70 Interphase Corporation

Strona 236

55536 PRI RAS Communications Controller Users Guide 715Setting Up WANFirmware and HardwareOverviewThe WAN Adapters Setup utility enables you to manage

Strona 237

Starting the WAN Adapters Setup Utility72 Interphase CorporationStarting the WAN Adapters Setup UtilityNOTEThe 5536-DM RAS is listed as the 5536-1P-PR

Strona 238 - 218 Interphase Corporation

Chapter 5: Setting Up WAN Firmware and Hardware5536 PRI RAS Communications Controller Users Guide 73When you start the utility, the WAN Adapters Setup

Strona 239

Firmware Management74 Interphase CorporationFirmware ManagementThe Firmware section of the WAN Adapters Setup dialog box displays firmware information

Strona 240

Chapter 5: Setting Up WAN Firmware and Hardware5536 PRI RAS Communications Controller Users Guide 75Use the following buttons to set up firmware infor

Strona 241

Hardware Management76 Interphase CorporationHardware ManagementThe Cards section of the WAN Adapters Setup dialog box displays all the 5536 WAN boards

Strona 242

Chapter 5: Setting Up WAN Firmware and Hardware5536 PRI RAS Communications Controller Users Guide 77Setting Up Card PropertiesUse the Card Properties

Strona 243

Hardware Management78 Interphase CorporationMost of the card properties are determined by hardware features and cannot be changed. Only the MVIP Bus c

Strona 244

Chapter 5: Setting Up WAN Firmware and Hardware5536 PRI RAS Communications Controller Users Guide 792. In the First Port field, if you do not want to

Komentarze do niniejszej Instrukcji

Brak uwag